Norklad 100 M - 100% Solids Epoxy Clear Coat 1500+ sq/ft

  • Model: OCCN100M-15
  • Manufactured by: Original Color Chips Company

15-Gallon Kit

Norklad 100-M
is a two part 100% solids epoxy broadcast coat that can be filled with decorative chips and colored sand mixtures to provide an infinite array of color schemes or patterns. It is 100% solids therefore has low odor, no flammability, and is self-leveling. When applied at 100 to 1..

Please Choose:
Hazmat Shipping Fee

Price :
$1432.03

15-Gallon Kit

Norklad 100-M
is a two part 100% solids epoxy broadcast coat that can be filled with decorative chips and colored sand mixtures to provide an infinite array of color schemes or patterns. It is 100% solids therefore has low odor, no flammability, and is self-leveling. When applied at 100 to 125 sq/ft per gallon, Norklad 100-M will self-level to a glasslike surface. The coverage rates on 100% solids epoxy are hard to judge due to the fact that you can spread it as thick or thin as you want, there is no shrinkage. (what you put down is what you get). 3-gal kits of Norklad 100-M can easily be applied across a 2-car garage.

When to use Norklad 100-M: 100% solids is recommended for warehouses, kitchens, restrooms, and other areas where either a high build clear product is needed or where a decorative filled floor is desired. Ideal for full broadcast terrazzo or colorchip floors. 100% solids is the industry standard for high-end commercial epoxy flooring.

Norklad 100-M 100% Solids Clear Coat Product Data Sheet

 

SOLIDS BY WEIGHT: 100%SOLIDS BY VOLUME: 100%VOLATILE ORGANIC CONTENT: Zero pounds per gallonCOLOR: ClearRECOMMENDED FILM THICKNESS: 16-18 milsCOVERAGE PER GALLON: 90-100 square feet per gallon @ 16-18 milsPACKAGING INFORMATION
3 gallon kits (2.95 gallons net approximately)
15 gallon kits (also available - please contact us for pricing and availability) MIX RATIO: 9.0 pounds part A (.99 gallons) to 4.15 pounds part B (.49 gallons) (volumes approx.)FINISH CHARACTERISTICS: Gloss (60 to 90 @ 60 degrees @ Erichsen glossmeter)ABRASION RESISTANCE: Taber abraser CS-17 calibrase wheel with 1000 gram total load and 500 cycles = 36 mg lossFLEXURAL STRENGTH: 7,400 psi @ ASTM D790COMPRESSIVE STRENGTH: 11,200 psi @ ASTM D695ADHESION: 350 psi @ elcometer (concrete failure, no delamination)VISCOSITY: Mixed = 700-1000 cps (typical)TENSILE STRENGTH: 7,600 psi @ ASTM D638ULTIMATE ELONGATION: 4.1%GARDNER VARIABLE IMPACTOR: 50 inch pounds direct – passedHARDNESS: Shore D = 81CURE SCHEDULE: pot life – 1 1/2 gallon volume ……..……... 20-30 minutes @ 70° F
tack free (dry to touch)…………....…………..…6-8 hours @ 70° F
recoat or topcoat.....…………….…………..... 10-16 hours @ 70°F
light foot traffic...…………………………..……14-18 hours @ 70°F
full cure (heavy traffic)... ………..…………...…....2-7 days @ 70°FAPPLICATION TEMPERATURE: 55-90 degrees FCHEMICAL RESISTANCE:REAGENT RATING
butanol C
xylene C
1, 1, 1 trichloroethane B
MEK A
methanol A
ethyl alcohol C
skydrol B
10% sodium hydroxide E
50% sodium hydroxide D
10% sulfuric acid C
70% sulfuric acid A
10% HC1 (aq) C
5% acetic acid BRating key: A - not recommended, B - 2 hour term splash spill, C - 8 hour term splash spill, D - 72 hour immersion, E - long term immersion. NOTE: extensive chemical resistance information is available through your sales representative.TOPCOAT: Urethane topcoat is recommended for added UV-Resistance. Norklad 100-M can easily coat over any solvent or waterborne epoxies. If used alone, it is recommended that a primer coat be used to prevent outgassing/blistering. *For best results, apply with a ¼” nap roller and/or squeegee.

 

SURFACE PREPARATION: The most suitable surface preparation would be a fine brush blast (shot blast or diamond grind) to remove all laitance and provide a suitable profile. All dirt, foreign contaminants, oil and laitance must be removed to assure a trouble free bond to the substrate. A test should be made to determine that the concrete is dry; this can be done by placing a 4'x4' plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating. The plastic sheet testing is also a good method to determine if any hydrostatic pressure problems exist that may later cause disbonding. Apply your basecoat and colorchips and allow to sufficiently cure. (wait until you can no longer leave an imprint of your finger in the coating. i. PRODUCT MIXING: This product has a mix ratio of 9.0# part A to 4.15# part B. Standard packages are packaged in 3-gal kits. (1 gal of part a (resen) and half gallon of part b (hardener). They are in pre-measured kits and should be mixed as supplied in the kit. We highly recommend that the kits not be broken down unless suitable weighing equipment is available. After the two parts are combined, mix well with slow speed mixing equipment such as a jiffy mixer until the material is thoroughly mixed and streak free. After mixing, transfer the mixed material to another pail (the transfer pail) and again remix. The material in the transfer pail is now ready to be applied onto your basecoat. Improper mixing may result in product failure.PRODUCT APPLICATION: The mixed material can be applied by brush, roller or a serrated squeegee and then back rolled as long as the appropriate thickness recommendations are maintained. Then broadcast aggregate into the coating while wet. Maintain temperatures and relative humidity within the recommended ranges during the application and curing process. If concrete conditions or over aggressive mixing causes air entrapment, then an air release roller tool should be used prior to the coating tacking off. This product can be used with random chip broadcasts, full chip broadcasts, or colored quartz. RECOAT OR TOPCOATING: If you opt to recoat or topcoat this product, you must first be sure that the coating has tacked off before recoating. Always remember that colder temperatures will require more cure time for the product before recoating or topcoating can commence. Before recoating or topcoating, check the coating to insure no epoxy blushes were developed (a whitish, greasy film or deglossing). If a blush is present, it must be removed prior to topcoating or recoating. We recommend topcoating with a urethane product to assist in UV-resistance.CLEANUP: Use xylol xylene.

WE CANNOT EXPEDITE THIS ITEM:  Some components in this flooring system may not be eligible for expedited shipping (Next Day Air, 2nd Day Air, or 3-day Select) because they are considered hazardous materials and may not be allowed on airplanes. For rush shipment inquiries please contact us at 586-771-6500 to discuss the fastest shipping options to your location